{"product_id":"overfill-alarm-battery-operated","title":"Overfill Alarm - Battery Operated","description":"\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\" style=\"text-align: start;\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch2\u003eOverfill Alarm\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eThis is a Constant Monitoring Alarm, and not \u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ea “push to test” type.\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eThe system consists of a weighted float switch that is connected with a 3m fuel resistant cable to the weatherproof High-level alarm box, containing the visual and audible alarms.  The high-level alarm is designed to provide visual and audible alarms whenever a predetermined level, in a fuel storage tank, is reached.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eSuitable for heating oil, diesel, biodiesel blends up to B100, lubricants.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eBattery operated (Battery supplied, type PP3 x1).\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eWeatherproof to IP65.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCompact design for use in confined spaces, 90mm square.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eHigh power alarm sounder 97 db at 1m.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFlashing light on top of unit.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eMute button stops the sounder, light still flashes.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFloat switch supplied with 5m cable.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003e2 year battery life, if tested weekly with no alarms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eThe PETRO high-level alarm will operate when the float switch is activated by a rising liquid level in the fuel storage tank.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe alarm will sound as a rising beep every 2.5 seconds and the light will flash simultaneously.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eTo silence the alarm, press the green button.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe light will continue to flash until the liquid level in the tank drops below the level of the float switch.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe battery will power the PETRO high-level alarm for 72 hours in full alarm mode with both the sounder and light activated.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eLow battery power is indicated by a short beep every 25 seconds.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eWhen the battery is low and the PETRO high-level alarm is activated.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe alarm will sound as a rising beep every 5 seconds to conserve power.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe light will flash every 25 seconds in normal operation (not in alarm mode) to indicate that the PETRO high-level alarm is operating correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWARNINGS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eThe high level alarm MUST NOT be used to monitor petrol (gasoline) or other flammable liquids.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eIt is designed for use with diesel, gas oil, water, lubricants and heating oil.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eIt must not be sited adjacent to a petrol dispenser or in any other hazardous zone.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eInstallation of this equipment should be carried out by a qualified fuel installation contractor.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe installation must conform to all relevant electrical and local authority regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAULT INDICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eIf the float switch is disconnected or the cable has been cut off the PETRO high level alarm will emit a short beep every 5 seconds.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eThe light and sounder can be tested at any time by pressing the green button once.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eIf the PETRO high-level alarm is functioning correctly a short series of beeps will sound and the light will flash.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eINSTALLATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eUsing the mounting lugs provided, fix the High-level alarm box in the position required ensuring the light and green button are located at the top.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFeed the float switch through a hole\/port in the top of the fuel storage tank. Position the float switch so it will be activated when the fuel level in the tank reaches the required maximum height and secure in position using the p-clip and self tapping screw provided.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eRemove the high-level alarm box cover (2 screws on the front) and connect the battery connector to the battery.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003ePress green button on top of high-level alarm box. Ensure a series of short beeps can be heard and the light flashes.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eReplace cover and screw down firmly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eOrder online with Piusi Shop and get free shipping Australia-wide today!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 529px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 60.296875px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2016\/8873\/files\/Overfill_Alarm_HLABATS_DataSheet_2026.pdf?v=1774350085\" title=\"Overfill Alarm\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2377\/5935\/files\/pdf_download_icon_thumb.png?v=1514939206\" style=\"float: left;\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 455.703125px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2016\/8873\/files\/Overfill_Alarm_HLABATS_DataSheet_2026.pdf?v=1774350085\" title=\"Overfill Alarm\" target=\"_blank\"\u003e Product Data Sheet\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"PETRO","offers":[{"title":"Default Title","offer_id":46680044077241,"sku":"HLABATS","price":257.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2016\/8873\/files\/Overfill-Alarm-Battery-Operated_HLABATS.png?v=1774349938","url":"https:\/\/piusishop.com.au\/products\/overfill-alarm-battery-operated","provider":"PIUSI Shop","version":"1.0","type":"link"}